Description
Lincoln Quicklub QLS 401 Electric Grease Pump – Remote Control
The QLS 401 for Remote Control allows customers to be in control of the lubrication process. The 24 VDC models monitor system cycling with a proximity switch. An external timer or PLC controls the interval between lube cycles. The 120 VAC models have no cycle monitoring and are on/off controlled by the user’s external timer or PLC. The minimum pause time requirements should be followed when setting up the external controller. (Optional low-level control).
| Model No. | P40191401110 |
| Operating Voltage | – 24 VDC – 120 VAC – 50/60 Hz |
| Operating Current | – 24 VDC/1.0 A – 120 VAC/1.0 A |
| Operating Temperature | -10°F to 158°F/-25°C to 70°C |
| Number of Outlets | 6, 8, 12 or 18 |
| Reservoir Capacity | 61″/1.0 L |
| Protection | NEMA 4 |
| Minimum Pause Time | 4 min. DC models/20 min. AC models |
| Maximum Operating Time | 25 min. DC models/15 min. AC models |
| Timer Memory | Indefinite |
| Maximum Operating Pressure | 3000 psi/205 bar |
| Output per Outlet & Cycle | approx. 0.0162″/approx. 0.2 cm. |
| Lubricant | up to NLGI 2 grease |
| Weight | 12.5 lbs./5.7 kg. |
Explore more from our collection.




Reviews